Applications
Retrofit Assemblies
For these and other Retrofit Assembly Drawings in PDF format visit
GenieClip™ Downloads.
GenieClip™ Benefits
- Increase IIC by 8-12 dB in floor ceiling retrofit assemblies
- Increase STC by 12-18 dB in wall retrofit assemblies
- Retrofit directly to existing ceiling or wall
- Greater STC than other popular retrofit solutions
Floor-Ceiling Assembly

Wall Assembly

Note: Resilient channel failure is a common observation by Acoustical Engineers.
Short circuited resilient channel results in up to a 10 STC point reduction.
LoVerde, J., & Dong, W. (2009). Quantitative comparisons of resilient channel designs and installation methods.
The GenieClip™ is proven to:
- Meet building codes for fire and sound
- Prevent costly litigation and reconstruction
Importance of Engineered Elastomer
| Isolation Clip | Durometer | Dynamic Stiffness | STC* |
|---|---|---|---|
| GenieClip™ | 37 | 11.3 N/mm | 57 |
| Isomax™ | 56 | 21.6 N/mm | 57** |
| RSIC-1™ | 57 | 21.2 N/mm | 56 |
| RSIC-V™ | No Rubber | No Rubber | 52 |
* 2x4 Wood stud 16" OC, 1 layer of 5/8" Type X GWB on each side with 3.5" Insulation
** Test conducted with 5.5" Insulation
** Test conducted with 5.5" Insulation
This information is available for download as a PDF in the GenieClip™ Product Brochure.