Floor-Ceiling Assemblies

For these and other Floor-Ceiling Assembly Drawings in PDF format visit GenieClip™ Downloads.

GenieClip™ Benefits

  • Excellent low frequency performance allows for design options in wood construction
  • Concrete slab results with significant broad-band sound reduction
  • Multi-family — Ideal for mechanical rooms, elevator shafts and fitness areas. For more information see: Apartment Construction

Wood Truss Laboratory Test

With Gypsum Concrete:
IIC = 52, STC = 55

  • Additional Laboratory test with above assembly:
    Tile: With 1/16" GenieMat RST02 IIC 55, STC 55
  • Field test for above assembly with engineered wood and 1/8" felt underlayment: FIIC 54

Without Gypsum Concrete:
IIC = 56, STC = 54

  • With Engineered Wood: IIC 53, STC 53

Concrete Slab Laboratory Test

IIC = 60, STC = 62

  • With 3/16" GenieMat RST05: IIC 55, STC 62
  • Field test with 1/2" rubber underlayment: FIIC 65

This information is available for download as a PDF in the GenieClip™ Product Brochure.