Floor-Ceiling Assemblies
For these and other Floor-Ceiling Assembly Drawings in PDF format visit GenieClip™ Downloads.
GenieClip™ Benefits
- Excellent low frequency performance allows for design options in wood construction
- Concrete slab results with significant broad-band sound reduction
- Multi-family — Ideal for mechanical rooms, elevator shafts and fitness areas. For more information see: Apartment Construction
Wood Truss Laboratory Test
With Gypsum Concrete:
IIC = 52, STC = 55

- Additional Laboratory test with above assembly:
Tile: With 1/16" GenieMat RST02 IIC 55, STC 55 - Field test for above assembly with engineered wood and 1/8" felt underlayment: FIIC 54
Without Gypsum Concrete:
IIC = 56, STC = 54

- With Engineered Wood: IIC 53, STC 53
Concrete Slab Laboratory Test
IIC = 60, STC = 62

- With 3/16" GenieMat RST05: IIC 55, STC 62
- Field test with 1/2" rubber underlayment: FIIC 65
This information is available for download as a PDF in the GenieClip™ Product Brochure.